Deactivation of oxidation and SCR catalysts used in flue gas cleaning by exposure to aerosols of high- and low melting point salts, potassium salts and zinc chloride
For the purpose of this deactivation study, Pt- and vanadia supported catalysts were used. The catalysts have been exposed to aerosol particles of inorganic salts, with high- or low melting points. The average diameter of the generated salt particle was kept constant at around 70 nm. The aerosol particle penetration depth for the samples exposed to potassium salt, was 1 μm as measured by scanning