Sökresultat

Filtyp

Din sökning på "fc 26 coins Buyfc26coins.com is EA Sports official for FC 26 coins The service is fast reliable great..3MIY" gav 55692 sökträffar

Remission maintenance in acute myeloid leukemia: impact of functional histamine H-2 receptors expressed by leukemic cells

Post-consolidation immunotherapy with histamine dihydrochloride and interleukin-2 has been shown to improve leukemia-free survival in acute myeloid leukemia in a phase III trial. For this study, treatment efficacy was determined among 145 trial patients with morphological forms of acute myeloid leukemia as defined by the French-American-British classification. Leukemia-free survival was strongly i

The neuroprotective effect of 2-oxoglutarate in the experimental ischemia of hippocampus

In this study we investigated the potential neuroprotective effect of 2-oxoglutarate (2-OG) on the hippocampus in the transient vessel occlusion ischemia model in the Mongolian gerbil. The morphological and biochemical studies were performed at 7 days after occlusion of carotid arteries. The acute reduction of NeuN-positive neurons in the CA1 pyramidal layer of the hippocampus was accompanied by i

The potential impact of new diagnostic criteria on the frequency of gestational diabetes mellitus in Sweden.

The International Association of Diabetes and Pregnancy Study Groups (IADPSG) has suggested new diagnostic criteria for gestational diabetes mellitus. Many centers in Europe still use the World Health Organization (WHO) criteria. In southern Sweden we use the 2-h threshold of the European Association for the Study of Diabetes criteria based on universal screening with a 75-g oral glucose tolerance

Automatic Measurements of Diameter, Distension and Intima Media Thickness of the Aorta in Premature Rabbit Pups Using B-Mode Images.

To improve cardiovascular research, there is a growing need for arterial characterization in small animals. We developed a method, ARTIC (arterial characterization) for measuring lumen diameter, distension and intima media thickness (IMT). In this study ARTIC was used to automatically characterize the aorta of premature rabbit pups. Automatic measurements were compared with manual measurements, bo

Measurement of the production of a W boson in association with a charm quark in pp collisions at root s=7 TeV with the ATLAS detector

The production of a W boson in association with a single charm quark is studied using 4.6 fb(-1) of pp collision data at root s = 7 TeV collected with the ATLAS detector at the Large Hadron Collider. In events in which a W boson decays to an electron or muon, the charm quark is tagged either by its semileptonic decay to a muon or by the presence of a charmed meson. The integrated and differential

T wave alternans in experimental myocardial infarction: Time course and predictive value for the assessment of myocardial damage.

BACKGROUND: T-wave alternans (TWA) is associated with prognosis after myocardial infarction (MI), however its link to the extent of ischemic injury has not been clarified. We analyzed the course of TWA and its relation to myocardial damage in experimental myocardial infarction. METHODS: In 21 pigs, infarction was induced by 40-minute long balloon inflation in LAD under continuous 12-lead ECG monit

Limited spread of penicillin-nonsusceptible pneumococci, Skane County, Sweden

In response to increasing frequencies of penicillin-non-susceptible pneumococci (PNSP), for which the MIC of penicillin was greater than or equal to0.12 mg/L, in Sk (a) over circle ne County, southern Sweden, national recommendations were initiated in 1995 to limit the spread of pneumococci with high MICs (greater than or equal to0.5 mg/L) of penicillin (PRP), especially among children of preschoo

Demographic transition of the Swedish cystic fibrosis community--results of modern care.

Assessing the results of modern cystic fibrosis (CF)-care and estimating the future population and its demography is important to evaluate the treatment regimens and to calculate the future needs of health-care resources.This paper updates previous incidence calculations. It assesses the results of modern CF-care in terms of survival and changing demography in Sweden. The incidence of CF in Sweden

Transvaginal Doppler examination of uteri with myomas

The uterine arteries and arteries in the wall and core of myomas were examined with transvaginal color and spectral Doppler ultrasound in 28 premenopausal and 17 postmenopausal women with uterine myomas. Eighteen premenopausal women and 100 postmenopausal women without myomas served as the controls for uterine artery Doppler measurements. The respective median time-averaged maximum velocity and pu

Accuracy of the quantification of organ activity from planar gamma camera images

The accuracy in determination of organ activity of Tc-99m was investigated, with activity estimated from gamma camera images of phantoms, using the, conjugate view method. The accuracy depends on several parameters such as the choice of background correction method, the accuracy in determination of the effective attenuation coefficient and the thickness of the body and organs and on the determinat

Measurements of the electron and muon inclusive cross-sections in proton-proton collisions at root s=7 TeV with the ATLAS detector

This Letter presents measurements of the differential cross-sections for inclusive electron and muon production in proton-proton collisions at a centre-of-mass energy of root s = 7 TeV, using data collected by the ATLAS detector at the LHC. The muon cross-section is measured as a function of p(T) in the range 4 < p(T) < 100 GeV and within pseudorapidity vertical bar eta vertical bar < 2.5. In addi

Smooth terminating bands in Te-112: Particle-hole induced collectivity

The Gammasphere spectrometer, in conjunction with the Microball charged-particle array, was used to investigate high-spin states in Te-112 via Ni-58(Ni-58, 4p gamma) reactions at 240 and 250 MeV. Several smooth terminating bands were established, and lifetime measurements were performed for the strongest one using the Doppler-shift attenuation method. Results obtained in the spin range 18-32h yiel