Study of different SX-700 monochromator designs for the undulator beamline (BL51) at MAX-lab
Different designs of the SX-700 plane grating monochromator have been investigated for the undulator beamline (51) by using analytical considerations and carrying out ray tracing calculations. The most important modifications of the original design are those where the ellipsoidal focusing mirror has been replaced by a plane elliptical or by a spherical mirror. A significant advantage of the spheri